POWER SPECIFICATIONS FOR NXAMP4x1 |
Number of amplifiers channels | 4x channels, 2 by 2 bridgeable |
Max. output voltage (no load) | 4 x 105Volts |
Max. output power (8Ω) | 4 x 600W |
Max. output power (4Ω) | 4 x 900W |
Max. output power (2Ω) | 4 x 1300W |
Power consumption (Standby) | 10W |
Power consumption (Idle) | 100W |
Power consumption (1/8 Power) | 1100W |
COMMON NXAMP SPECIFICATIONS FROM ANALOG IN TO POWER OUT |
Analog Inputs channels | 4x channels, analogue inputs on XLR 3 with a second XLR 3 for linking |
Frequency response | ±0.5dB from 10Hz to 20KHz |
Input Impedance | 20KΩ |
Max Input Level | +28dBu |
Dynamic Range | All Channels = 105dB unweighted |
THD + Noise | Typical 0.1% flat setup |
Latency time | 500us on a flat setup |
Power Supply | Dedicated version for 100 ~ 120Volts or 220 ~ 240Volts |
COMMON NXAMP FEATURES |
Audio Inputs | 4x balanced analogue inputs on XLR3 with a second XLR3 for linking, using 24bit converters.4x digital inputs via the optional network card slot at the back. |
Power Outputs | 4x Speakon outputs using internal power relay for automatic output assignmentregarding setup. |
| |
RS232 port | Allow firmware upgrade for software improvement and new cabinet setups. |
GPIO port | 5x Global Purpose Inputs and 8x Global Purpose Outputs for simple remote controland monitoring. |
Processing | Two DSPs, 24bit data with 48bit accumulator. 700MIPS. |
Front Panel | On/Off Mains switch, Select Wheel, Menu A and Menu B buttons, 40 characters by2 lines display. Amp protect, Stand-by and power LED’s. Then for each channel: volumeindicator (15x LEDs), Individual Mute buttons and red LED, output current signal greenled, Speaker Protection yellow LED, Amp. Peak red LED. |
Rear Panel | 1 (NXAMP4x1) or 2 (NXAMP4x4) mains socket; RS232 serial communications connector;GPIO port, Expansion slot for networking audio extension card, 4 XLR inputs with link and 4 Speakon 4 outputs. |
Dimensions & Weight | NXAMP4x1: 3U 19” Rack - 457 mm (18”) Depth - 16.5kg (33lbs) net |
NXAMP USER CONTROLS |
System Selection | Allows control across all NEXO ranges. |
System Set-up | Within the selected range, if possible, allows cabinets to be set for passive or active mode,wideband or crossover mode, choose among available crossover point, cardioid orsupercardioid mode. |
Protection | Multiple Peak Limiters fitted for both selected cabinet and amplifier. Multiple Acceleration,Displacement and Temperature protections on every channel. Inter-channel regulation. |
Delay | Up to 150m (330 ft.) of delay in 10cm (.4in ) steps |
Input Patching | Allows any of the 4x analogue (or digital) inputs combination to be routed on each output. |
Output Gain | Global and inter-channel gain ±6dB in 0.5dB steps. |
Volume control | Each channel with 16x steps from – inf dB to 0dB. |
Save/Recall | Set-up Stores up to 40x user set-ups; On- the-fly recall, without mute or glitches forinstant comparison. |
Array EQ | LF or HF shelving filters to compensate ground or stacking effects, ±6dB,frequency factory tuned. |
Security Mode | Password protected for Read-Only or Remote-Only Mode. |
Remote control | Full remote control via the Ethersound protocol and ESmonitor software. |
Certification | UL, SEMKO (CE), CCC, KOREA, TSS, PSE |
Green status | Compliant with ROHS and WEEE directive |