| 特点:高效率,高可靠、低成本开关选择输入电压范围100%满负荷烧机测试保护特性:短路/过载工作频率25KHz空气冷却1年保质期尺寸: 199*98*38mm (L*W*H) | |
|
| 型号 | S-100-3 | S-100-5 | S-100-7.5 | S-100-12 | S-100-15 | S-100-18 | S-100-24 | S-100-27 | S-100-48 |
| 输出 | 直流输出电压 | 3V | 5V | 7.5V | 12V | 15V | 18V | 24V | 27V | 48V |
| 输出电压容差(注3) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
| 额定输出电流(注4) | 20A | 20A | 13.6A | 8.5A | 6.7A | 5.6A | 4.5A | 3.7A | 2A |
| 输出电流范围 | 0-20A | 0-20A | 0-13.6A | 0-8.5A | 0-6.7A | 0-5.6A | 0-4.5A | 0-3.7A | 0-2A |
| 输出功率 | 60W | 100W | 102W | 102W | 100.5W | 100.8W | 108W | 99.9W | 96W |
| 纹波及噪音(注2) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 150mVp-p |
| 直流电压可调范围 | -5%,+10% | -5%,+10% | ±10% | ±10% | ±10% | ±10% | ±10% | -4%,+18% | ±10% |
| 启动、上升、保持时间 | 200ms,80ms,20ms满载 |
| 输入 | 输入电压范围 | 85~132 VAC/180~264VAC 47~63 Hz;由开关选择255~370VDC |
| 交流输入电流 | 2.4A/115 V 1.2A/ 230 V |
| 效率 | 70% | 78% | 80% | 81% | 81% | 82% | 84% | 84% | 84% |
| 冲击电流 | 冷启动电流30A/115V 60A/230V |
| 漏电流 | <1 mA/240VAC |
| 保护特性 | 过载保护 | 115%~165% |
| 保护方式:切断输出,重新启动 |
| 环境 | 工作温度、湿度 | -10℃~+60℃;20%~90 %RH |
| 保存温度、湿度 | -20℃~+85℃;10%~95 %RH |
| 抗震性 | 10~500Hz,2G 10min./1周期,时长60分钟,各轴 |
| 安全 | 耐压性 | 输入输出间:1.5KVAC 输入与地:1.5KVAC 输出与地:0.5KVAC |
| 绝缘电阻 | 输入输出间,输入与地,输出与地: 100M Ohms/500VDC |
| 符合标准 | 安全标准 | 符合UL1012 |
| EMC标准 | Design refer to FCC Part15 J Conduction Class B |
| 其它 | 重量 | 0.62Kg |
| 包装 | 30pcs/19Kg/1.22CUFT |
| 备注 | 所有参数在未特别指明时,都是在230VAC电压输入,额定负载和25℃条件下测量所得值。纹波和噪声电压是在20MHz带宽示波器带12英寸双绞线末端加0.1μ和47μ电容时测得。容差是电压设定误差、电压调整率和电流调整率之总和。具体输出电流见输出降额曲线。 |